Use este identificador para citar ou linkar para este item:
http://repositorioinstitucional.uea.edu.br//handle/riuea/750
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Souza, Wanderleia Monteiro de | - |
dc.date.available | 2017-12-07T13:12:14Z | - |
dc.date.issued | 2017-12-05 | - |
dc.identifier.uri | http://repositorioinstitucional.uea.edu.br/handle/riuea/750 | - |
dc.description | Os cimentos endodônticos são responsáveis pelo aprisionamento de bactérias remanescentes e a vedação dos sistemas de canais radiculares, possuem propriedades que podem ter os seguintes grupos: antimicrobiano, biológico e físico-químico. As propriedades físico-químicas dos cimentos têm sido bastante estudadas avaliação da sua efetividade. O objetivo deste estudo foi comparar as propriedades físico-químicas de escoamento e estabilidade dimensional entre os cimentos obturadores endodônticos Sealer 26 e Endomethasone N, sob a Especificação n°57 da ANSI/ADA. Para o teste de escoamento foram realizadas 5 repetições do experimento para cada cimento, após 10 minutos com uso de um paquímetro digital foram medidos o maior e menor diâmetro e obteve-se a média aritmética. A estabilidade dimensional foi avaliada por meio da média aritmética de 5 medições, realizadas com paquímetro digital, do comprimento dos corpos-de-prova, antes e após estes terem sido imersos por 30 dias em recipientes com água destilada e deionizada a 37°C. O grupo do cimento Sealer 26 (55,012± 5,85), promoveu um maior escoamento quando comparado com o grupo Endomethasone N (42,444± 2,96). Em relação a estabilidade dimensional, verificou-se que nenhum dos cimentos apresentou resultados satisfatórios com base nas determinações da Especificação n° 57 da ANSI/ADA tendo o grupo do cimento Sealer 26 (0,50 ± 0,72) e o grupo Endomethasone N (0,44 ± 0,59). Para o escoamento dos cimentos endodônticos Endomethasone N e Sealer 26, os mesmos encontram-se de acordo com a Especificação n° 57 da ANSI/ADA. Para a alteração dimensional, verificou-se que o Endomethasone N e Sealer 26 não apresentaram resultados que atendesse a Especificação n° 57 da ANSI/ADA. | pt_BR |
dc.description.abstract | Endodontic sealres are responsible for the entrapment of remaining bacteria and the sealing of root canal systems. They have properties that can have the following groups: antimicrobial, biological and physicochemical. The physical-chemical properties of the cements have been well studied evaluation of their effectiveness. The objective of this study was to compare the physical-chemical properties of flow and dimensional stability between Sealer 26 and Endomethasone N endodontic sealers, under ANSI / ADA Specification No. 57. For the flow test, 5 replicates of the experiment were performed for each root canal sealer, after 10 minutes using a digital caliper the largest and smallest diameter were measured and the arithmetic mean was obtained. The dimensional stability was evaluated by means of the arithmetic mean of 5 measurements made with a digital caliper of the length of the specimens before and after they were immersed for 30 days in containers with distilled water and deionized at 37 ° C. The Sealer 26 group (55.012 ± 5.85) promoted a higher flow rate when compared to the Endomethasone N group (42.444 ± 2.96). For the dimensional stability test, none of the cements showed satisfactory results based on the determinations of ANSI / ADA Specification No. 57, with the Sealer 26 group (0.50 ± 0.72) and the Endomethasone N group (0.44 ± 0.59). For the flow test, Endomethasone N and Sealer 26 endodontic they were in accordance with ANSI / ADA Specification No. 57. For dimensional stability, it was found that Endomethasone N and Sealer 26 did not present results that met ANSI / ADA Specification No. 57. | pt_BR |
dc.language.iso | por | pt_BR |
dc.publisher | Universidade do Estado do Amazonas | pt_BR |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | * |
dc.subject | Sealer 26 | pt_BR |
dc.subject | Endomethasone N | pt_BR |
dc.subject | Estabilidade dimensional | pt_BR |
dc.subject | Dimensional stability | pt_BR |
dc.title | Propriedades físico-químicas dos cimentos obturadores endodônticos Sealer 26 e endomethasone N em relação à estabilidade dimensional e escoamento | pt_BR |
dc.title.alternative | Physical and chemical properties of endodontic sealer cements sealer 26 and endomethasone N in relation to dimensional stability and flow | pt_BR |
dc.type | Trabalho de Conclusão de Curso | pt_BR |
dc.date.accessioned | 2017-12-07T13:12:14Z | - |
Aparece nas coleções: | ESA - Trabalho de Conclusão de Curso Graduação |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Propriedades físico-químicas dos cimentos obturadores endodônticos sealer 26 e endomethasone N em relação à estabilidade dimensional e escoamento.pdf | 1,89 MB | Adobe PDF | Visualizar/Abrir |
Este item está licenciada sob uma Licença Creative Commons